55
• Auto-Disarm Schedule
Uploads the Auto-Disarm times and the day assignments programmed in the
three Auto-Arm schedules.
• Troubles/Memory
Uploads the status of troubles. “Yes” will appear beside the Trouble Conditions
list to indicate which troubles are present; “No” will appear beside those Trouble
Conditions that are not present. An “
*
” will appear beside the Trouble Conditions
that are in Alarm Memory.
• System Times
Uploads the current system time, date and day of the week.
• Additional Hardware (DC1664 only)
Displays whether or not the control panel’s memory has been expanded with the
addition of an MEX2 unit.
Arm/Disarm System
This function is used to arm and disarm groups. When selected, a menu will be
displayed to allow the system to be armed or disarmed. A second menu will be
displayed to determine which Group is to be armed or disarmed. Use the mouse or
press the [SPACE] bar to tag the groups that are to be armed or disarmed.
Bypass Zones
This function is used to bypass zones on the DC1664. Note that zones may be
bypassed even when the system is armed.
A Bypass Status Screen for all 64 zones will be displayed. “Bypassed” will appear
beside each zone that is presently bypassed. Use the mouse or press the [SPACE]
bar to tag the zones that are to be bypassed.
Press [F2] to bypass zones using the bypasses recorded in the Bypass History.
Press [F5] to remove the bypasses from all zones.
Quick Arm
This function is used to enable or disable the Quick Arm function.
Door Chime
This function is used to enable the Door Chime function. A Door Chime Status Screen
for all 64 zones will be displayed. “Chime” will appear beside each zone that will
activate the Door Chime when opened. Use the mouse or press the [SPACE] bar to
tag the zones that are to chime.
Auto-Arm Control
This function is for programming the Auto-Arm/Disarm Schedules. Times entered in
this section must be entered in the 24-hour format (for example, 4:00 pm would be
entered as 16:00).
Panel Date and Time
This function is for setting the time and date in the panel. The time is entered in the 24-
hour format.