2.4 Create a Customer Work File
If this is your first session, there will be no Customer Work Files present in the Work
File directory. In this case select the “Create A File” function from the Main Menu. If
there are any files present on the disk, the file names will be displayed along the right
side of the screen. To scroll through these names, use the [ARROW] keys, [PG UP]
and [PG DN] keys, or [HOME] and [END] Keys. The first item in creating a new file is
to enter the FILE NAME. You are limited to alphanumeric characters only for file
names. Several file names are reserved as default files for use by the DLS-1 Software:
PC1150 PC15 PC1552 PC1553 PC1555 PC1565 PC1575
PC155U PC15V2 PC15V3 PC15V4 PC15V3V P16 PC16
PC1664 PC25 PC2513 PC2525 PC2585 PC51 PC30
PC3077 PC307L PC40 PC41 PC412 PC42 PC422
PC5008 PC5012 PC5015 PC5082 PC5083 PC508U PC51
PC550 PC551 PC560 PC580 PC583 PC8423 PC90
These files contain the factory default settings of their respective control panels.
These settings are changeable through the Default File Maintenance function
selected from the Main Menu. If the file name you choose already exists, you will be
warned of that fact and asked if you wish to over-write the file. If you select “Yes”, the
old file will be deleted and a new one will be created in its place.
NOTE: By doing this you can quickly return a file to default settings.
Once you have entered a valid file name, you must select the type of panel the file is
to work with. Each panel has a unique file type and only that file type can be used to
communicate with the panel. For example, a PC3000 Work File may only be used to
communicate with and store data from a PC3000 control panel. From the list
presented, select the panel type. Note that for the PC5010, PC5008, PC4020,
PC4010, PC3000, PC2550, PC1555/1565, PC1550/PC1500, PC580/585, and PC550
there are different file versions. These version numbers represent software versions
of the control panels; for example, for a PC1500 with version 2.1 software, select
VER2.X. For the PC1550, you must select the VER1.X, VER2.X, VER3.X or VER4.X file.
After the panel type is selected, a window will appear which will allow you to select
which default file to use. Refer to Section 4.5 for information on creating default files.
For now, select “Factory”. The file will be immediately created and you will be
returned to the main menu.
The new work file which you have just created is an exact copy of the factory default
settings for the selected control panel.