8 to 32 Zone Expandable Hybrid Security System
Output Modules
PC5204 - Power Output Module
Provides 1 Amp @ 12VDC
aux power
Includes 4 fully programmable
high current switched outputs
rated at 1 Amp @ 12VDC
Output-1 also supervised bell output
PC5208 Voltage Output Module
Provides 8 transistor switched
outputs rated at 50mA @ 12VDC
24 programmable output options
LCD5500Z
Multi-Language Message Keypad
Large backlit, two line
32 character display
5 programmable function
keys with 18 options
Connect up to 8
keypads, combination
LCD and/or LED
Plain language operation
Keypad can be assigned
as “global” or “partition”
Zone Expansion
PC5108 Alarm/5108L Video
Zone Expanders
Expand system in 8 zone steps
Full NC/EOL/DEOL supervision
PC5108L is c/w 8 camera inputs
for Downlook
®
…packed with options that make Power832 the most innovative security system on the market today!
PC5400
RS 232 Printer/DVACS Interface
Use as DVACS communications or printer
interface
Print time and date stamped report of:
alarms, openings/closings, diagnostic
messages
Supports any 300, 1200, 2400,
4800 BPS serial printer
PC5010/5015Video
8 - 32 Zone Control Panel
8 programmable zones expandable
to 32 zones hardwired or wireless
Supervised bell output
One 2-wire smoke zone
Up to 14 programmable outputs:
- 1 high current PGM (300mA)
- 1 low current PGM (50mA)
2 partitions
37 access code: 32 user codes,
2 partition master, 1 system master
code, 2 hold-up codes
Upload/download
128 event buffer, time and date
stamped
PC5010 - Alarm only
PC5015* - Alarm plus Downlook
®
video control capability
PC5508Z/16Z/32Z
8, 16 or 32 Zone LED Keypads
Backlit keys and full annunciation
of system status
5 programmable function
keys with 18 options
4 keypad activated alarms (Panic,
Auxiliary, Fire, and Duress)
Keypads individually
supervised for tamper
Can be assigned as “global”
or “partition” keypad
Connect up to 8 keypads,
combination of LED and/or LCD
PC5508 - 8 zone LED Keypad
PC5516 - 16 zone LED Keypad
PC5532 - 32 zone LED Keypad
Compatible With All DSC Wireless
Controls and Detectors
Wireless Controls:
WLS908 Wireless Panic Pendant*
WLS909 Wireless Key
WLS910 Wireless Keypad
Wireless Detectors*:
WLS904 PIR Motion Detector
WLS906 Photoelectric Smoke Alarm
WLS907 Universal Transmitter
*each occupies one wireless zone
Supports 32 wireless zones,
16 WLS909 Wireless Keys,
and 4 WLS910 Wireless Keypads
All wireless detectors are fully
supervised for communication integrity
900MHz True Spread Spectrum Technol-
ogy
Easy sensor enroll process
Wireless devices use standard
AA/AAA alkaline batteries
PC5132
Wireless Module
• 6 • • 7 •
WINNER
Product Achievement Award for
Intrusion Alarm Systems
Audio Station and Keypad mounted on a common backplate
Accredited Technician
Program
3Hr video library & companion
workbook
Designed to make experts of
installers and salespeople
Laptop Demo
The first demonstrator truly
designed for the dealer
A hands-on demo of all system
features in an attractive, easy to
carry, dealer and customer
friendly package
Hand-held Demo
Battery operated demo for
Power832 LCD keypad
Demonstrates stay arm, away
arm, and disarming system
Escort
5580
Telephone Access
Security & Building
Automation Control Module
Turns any touch-tone phone
into a keypad with most
standard functions
Module contains extensive
library of voice prompts
Choice of language – English,
French, or Spanish
Built-in Power Line
interface for up to 32
X-10 control devices
Program up to 16 schedules
and 8 control modes
Downlook
®
On-Site Sequential Switching
&
Still Frame Video Transmis-
sion
Requires PC5015 Control Panel &
PC5108L Video Zone Expander
All necessary programming
software built in to PC5015
control panel
PC5108L provides 8 video
inputs, one video output,
& 8 alarm zones
May be used standalone as an
on-site video switcher
Connect to Sur-Gard DLM-4L
Video Transmitter Module for
transmission to monitoring
station (see page 26)
EMS-100
Thermostat
Multi-stage auto-changeover
thermostat – 2 heat/2 cool
Requires Escort PC5580TC
module
System LCD keypads display
interior/exterior temperatures
Control building heating/cooling
from system keypads
Control building heating/cooling
from any local or remote
touchtone telephone
Schedule heating/cooling via
Power832 Escort scheduling
Interior/exterior sensors available
Interior temperature sensor
averaging for control
Integrated
Automation
Integrated
HVAC Control
Integrated
CCTV
*
Integrated
Audio
Intercom
& Central Station
Audio Monitoring
Local Intercom
Select Zone, listen/talk,
extend on-line time, hang up
Use up to 7 intercom stations
Fully featured with
page/answer, do not disturb,
nursery listen-in, broadcast,
and door bell function
Central Station
Audio Monitoring
operates via programmable
control tones from central station
PC5928 - Audio Interface Module
for intercom and Central
Station Audio Monitoring
PC5921 - Interior Station
PC5921EXT - Exterior Station
PC5921EXT-R - Exterior Station
with door chime relay
PC5904 - Two Way
Listen-In Station